Correction of misaligned slices in multi-slice cardiovascular magnetic resonance using slice-to-volume registration
Adam G Chandler3, Richard J Pinder1, Thomas Netsch2, Julia A Schnabel3, David J Hawkes3, Derek LG Hill3 and Reza Razavi1
1King's College London, Division of Imaging Sciences, St Thomas' Hospital, London, UK
2Philips Research, Hamburg, Germany
3Centre for Medical Image Computing, University College London, UK
author email corresponding author email
Journal of Cardiovascular Magnetic Resonance 2008,
10:13doi:10.1186/1532-429X-10-13
Published:
29 February 2008
Abstract
A popular technique to reduce respiratory motion for cardiovascular magnetic resonance is to perform a multi-slice acquisition in which a patient holds their breath multiple times during the scan. The feasibility of rigid slice-to-volume registration to correct for misalignments of slice stacks in such images due to differing breath-hold positions is explored. Experimental results indicate that slice-to-volume registration can compensate for the typical misalignments expected. Correction of slice misalignment results in anatomically more correct images, as well as improved left ventricular volume measurements. The interstudy reproducibility has also been improved reducing the number of samples needed for cardiac MR studies.