Rapid, routine evaluation of left ventricular diastolic function and left ventricular filling pressures during cardiac magnetic resonance imaging

Padmini Varadarajan* and Raas Pai

  • * Corresponding author: Padmini Varadarajan

Author Affiliations

Loma Linda University Medical Center, Loma Linda, CA, USA

For all author emails, please log on.

Journal of Cardiovascular Magnetic Resonance 2010, 12(Suppl 1):P265  doi:10.1186/1532-429X-12-S1-P265

The electronic version of this article is the complete one and can be found online at: http://jcmr-online.com/content/12/S1/P265


Published:21 January 2010

© 2010 Varadarajan and Pai; licensee BioMed Central Ltd.

Introduction

Left ventricular (LV) diastolic function and LV filling pressure is clinically important and is routinely assessed by echocardiography. Cardiac MRI (CMR) is increasingly used in practice. We investigated the feasibility of incorporating this in routine CMR examination.

Methods

A GE HDx 3 T system with 8 channel cardiac coil was used for CMR examination. Mitral and pulmonary vein flows were obtained in 130 consecutive patients. The short axis slice with mitral valve was then used to acquire phase contrast images with VENC of 1 m/sec. Next the long axis of the LV showing the pulmonary vein, usually the right upper was acquired. An in-plane image of the pulmonary vein was obtained. Next a through plane phase contrast image of the pulmonary vein was obtained with a VENC of 80 cm/sec. Phantom images at the same mitral and pulmonary vein levels were obtained at the end of the study to correct for background noise.

Results

Analyzable signals were obtained in all 117 patients with an average of 5 additional minutes. Mitral flow velocity signals were classified as normal, abnormal relaxation, pseudonormal and restrictive patterns using the standard criteria (figure 1). Pulmonary vein 'AR' wave duration relative to mitral 'A' wave duration was used to differentiate normal from pseudo-normal. Following patterns were noted: 19 abnormal relaxation, 1 pseudonormal, 1 restrictive, 1 atrial fibrillation with high filling pressure, 95 normal. Of the 26 with an echocardiogram within a month of CMR, 25 had fully concordant filling patterns.

Conclusion

1) Rapid, routine CMR assessment of LV diastolic function and LV filling pressure is feasible. 2) It correlates well with echocardiography and should be part of a complete CMR examination.