Time-resolved mr venography pre catheter-based ablation for atrial fibrillation

Objective

The purpose of this study was to evaluate Time-resolved MR venography (TR-MRV) of the pulmonary venous circulation using the time-resolved angiography with interleaved stochastic trajectories (TWIST) method of time-resolved MRA (TR-MRA) and compare it with the more commonly used conventional Contrast enhanced magnetic resonance angiography (CE-MRA) approach in atrial fibrillation patients referred for pre-ablation pulmonary vein mapping.

Background

Catheter-based ablation of the pulmonary veins prevents recurrence of atrial fibrillation in 70-80% of patients during the first year of follow-up1,2. CE-MRA depicts the left atrium and pulmonary veins with high spatial resolution, enabling accurate measurement of pulmonary vein ostia to be made with depiction of their relationship to other structures.1,3 Conventional CE-MRA however requires timing of contrast enhancement and produces images with overlap of venous and arterial structures, potentially obscuring pulmonary vein ostia. TR-MRA is an alternative to conventional CE-MRA and has been used successfully in other vascular territories.4 Such an approach may be particularly advantageous in the pulmonary circulation with its rapid arteriovenous transit time, allowing acquisition of pure pulmonary venous phase images with a simpler imaging protocol.

Material and methods

26 patients (15 males; age 60.0 ± 12.7y) referred for pre-ablation pulmonary vein mapping underwent both conventional CE-MRA and TR-MRV with TWIST. Imaging was performed on a 1.5 Tesla (MAGNETOM Avanto, Siemens Healthcare) MRI scanner. Source partition and MIP images were evaluated. Quantitative Analysis: Pulmonary vein ostium orthogonal dimensions were measured using double oblique multiplanar reformatting. Qualitative Analysis: For qualitative analysis, both source partition images and MIP images were assessed by two observers. Pulmonary vein conspicuity was scored on a scale of 1-4 (1=poor, 2=fair, 3=good, 4=excellent). The number of pulmonary veins (3 veins= common ostium, 4 veins = normal, 5 veins=accessory vein) was recorded.

Results

Orthogonal venous diameters were comparable for both TR-MRV and conventional CEMRA (1.34cm ± 0.37 vs 1.38cm ± 0.36, respectively); see Table 1. Visualization of pulmonary vein anatomy and variant anatomy was also similar for both techniques (fig 1).

Table 1 Comparison of the mean pulmonary diameter ± standard deviation (maximum; minimum values for TWIST and Conventional CE-MRA respectively.
Figure 1
figure 1

Comparison of accessory vein and common ostium detecting ability using a bar graph to quantify differences between conventional CE-MRA and TWIST TR-MRA. However, TWIST was superior in detecting common ostiums and slightly better than the conventional CE-MRA technique at identifying patients with both common ostiums and accessory veins. Finally, CE-MRA was slightly better overall for visualizing the pulmonary veins but had a greater margin of error. The TWIST technique, on the other hand, had slightly worse overall results but was more consistent in yielding high quality visualizations of the veins. The CE-MRA was able to identify the focal ostial stenosis present in one patient during the qualitative analysis while the TWISE was not.

Conclusion

We have demonstrated that TR-MRV using TWIST produces comparable anatomic images and pulmonary venous dimensions to the more widely used CEMRA technique. TR-MRV improves arterio-venous separation producing high resolution pulmonary venous phase images without arterial overlap.

References

  1. Hauser TH, et al: Europace. 2008

    Google Scholar 

  2. Wattigney WA, et al: Circulation. 2003

    Google Scholar 

  3. Maksimovi R, et al: European Radiology. 2006

    Google Scholar 

  4. Kim CY, et al: AJR. 2008

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Schonberger, M., Kino, A., Popescu, A. et al. Time-resolved mr venography pre catheter-based ablation for atrial fibrillation. J Cardiovasc Magn Reson 13 (Suppl 1), P234 (2011). https://doi.org/10.1186/1532-429X-13-S1-P234

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/1532-429X-13-S1-P234

Keywords