Email updates

Keep up to date with the latest news and content from Journal of Cardiovascular MR and BioMed Central.

Open Access Highly Accessed Correction

Correction: reproducibility of in-vivo diffusion tensor cardiovascular magnetic resonance in hypertrophic cardiomyopathy

Laura-Ann McGill12, Tevfik Ismail1, Sonia Nielles-Vallespin123, Pedro Ferreira12, Andrew D Scott12, Michael Roughton1, Philip J Kilner12, S Yen Ho12, Karen P McCarthy12, Peter D Gatehouse1, Ranil de Silva12, Peter Speier4, Thorsten Feiweier4, Choukkri Mekkaoui5, David E Sosnovik5, Sanjay K Prasad12, David N Firmin12* and Dudley J Pennell12

Author Affiliations

1 Cardiovascular Magnetic Resonance Unit, Royal Brompton Hospital, London, UK

2 National Heart and Lung Institute, Imperial College, London, UK

3 National Heart Lung and Blood Institute (NHLBI), National Institutes of Health (NIH), DHHS, Bethesda, MD, USA

4 MR R&D, Siemens AG Medical Solutions, Erlangen, Germany

5 Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA

For all author emails, please log on.

Journal of Cardiovascular Magnetic Resonance 2013, 15:22  doi:10.1186/1532-429X-15-22

The electronic version of this article is the complete one and can be found online at: http://jcmr-online.com/content/15/1/22


Received:19 February 2013
Accepted:19 February 2013
Published:28 February 2013

© 2013 McGill et al.; licensee BioMed Central Ltd.

This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Correction

Following publication of article [1] we noted an error in the methods section of our abstract in which we state: “Global MD was significantly higher in the septum than the reference lateral wall (0.784 ± 0.188 vs 0.750 ± 0.154 × 10-3 mm2/s, p < 0.001).” The word “Global” was not correct, and the reference value was incorrect, this should state: “MD was significantly higher in the septum than the reference lateral wall (0.784 ±0.188 vs 0.714 ±0.155 × 10-3 mm2/s, p <0.001).” All other information is correct, we apologize for any inconvenience caused by this error.

References

  1. McGill LA, Ismail T, Nielles-Vallespin S, Ferreira P, Scott AD, Roughton M, Kilner PJ, Ho SY, McCarthy KP, Gatehouse PD, de Silva R, Speier P, Feiweier T, Mekkaoui C, Sosnovik DE, Prasad SK, Firmin DN, Pennell DJ. Reproducibility of in-vivo diffusion tensor cardiovascular magnetic resonance in hypertrophic cardiomyopathy. J Cardiovasc Magn Reson. 2012; 14:86. PubMed Abstract | BioMed Central Full Text | PubMed Central Full Text OpenURL