Skip to main content

A case of a lesion containing an intracoronary thrombus detected as hyperintense plaque on T1-weighted cardiovascular magnetic resonance in a patient with silent myocardial ischemia

Abstract

Many investigators have speculated that hyperintense plaques (HIPs) of the carotid artery on noncontrast T1-weighted imaging (T1WI) in cardiovascular magnetic resonance indicate the presence of mural or intraplaque hemorrhage containing methemoglobin. However, coronary plaque imaging with T1WI is challenging, and the clinical significance of coronary HIPs on T1WI remains unknown. Incidentally, it is very rare to find an intracoronary thrombus at the culprit lesion site in patients in stable condition. This article reports the case of a lesion containing an intracoronary thrombus, detected as HIP on T1WI associated with the filter no-reflow phenomenon in a patient with silent myocardial ischemia.

Background

Many investigators have speculated that hyperintense plaques (HIPs) of the carotid artery on noncontrast T1-weighted imaging (T1WI) in cardiovascular magnetic resonance (CMR) indicate the presence of mural or intraplaque hemorrhage containing methemoglobin [1, 2]. Coronary plaque imaging with T1WI is challenging, and the clinical significance of coronary HIPs on T1WI remains unknown. Jansen et al. demonstrated that within 72 hours after the initial onset of symptoms, 10 of 18 patients with acute myocardial infarction (AMI) were found to have intracoronary thrombi as detected by invasive coronary angiography, and that HIPs on T1WI correctly identified the intracoronary thrombi [3]. Recently, we have shown that intraluminal HIPs on T1WI are related to the presence of intracoronary thrombi as detected by optical coherence tomography (OCT) imaging [4].

Previous studies by using intravascular ultrasonography [5] or OCT [6] showed that multiple unstable plaques, associated with plaque rupture, thin-cap fibroatheroma (TCFA), and intracoronary thrombi, were more common in patients with AMI than in those with stable angina pectoris (SAP). Recently, Kubo et al. demonstrated that intracoronary thrombi were not found in the culprit and nonculprit lesions of SAP patients, though they were observed in 100% and 8% of the culprit and nonculprit lesions, respectively, of AMI patients [6]. Thus, it is very rare to find an intracoronary thrombus at the culprit lesion site in patients in stable condition.

This article reports the case of a lesion containing an intracoronary thrombus, detected as HIP on T1WI associated with the filter no-reflow phenomenon in a patient with silent myocardial ischemia.

Case presentation

A 64-year-old man with a history of dyslipidemia and current smoking had undergone multislice computed tomography (MSCT) coronary angiography to exclude coronary artery disease, although he had been fully active and denied all symptoms. At that time, MSCT coronary angiography showed moderate stenosis in the mid left anterior descending artery (LAD) (Figure 1-A, B). One year later, follow-up MSCT coronary angiography was performed, and it showed a slight progression of the coronary stenosis (Figure 1-C, D). The results of his electrocardiography, echocardiography, and cardiac enzyme testing showed no abnormalities, but exercise stress thallium-201 single-photon emission computed tomography revealed apico-anterior myocardial ischemia (Figure 2). Whole-heart coronary MR angiography, using a 1.5 T MR system (Achieva, Philips Medical Systems, Best, the Netherlands), showed moderate coronary stenosis in the mid LAD (Figure 3-A), which is the same finding as that reported by MSCT angiography. Then, the coronary plaque image was obtained when a patient was breathing freely by using a three-dimensional T1WI inversion-recovery gradient-echo sequence with black-blood condition using a Look Locker sequence, fat-suppressed and radial k-space sampling in Y-Z plane (repetition time, 4.4 ms; echo time, 2.0 ms; flip angle, 20°; SENSE factor, 2.5; number of excitations, 2; navigator gating window of ±1.5 mm with diaphragm drift correction; field of view, 300 × 240 × 120 mm (rectangular field of view, 80%); acquisition matrix, 224 × 224; reconstruction matrix, 512 × 512 × 140, resulting in an acquired spatial resolution of 1.34 × 1.34 × 1.7 mm reconstructed to 0.6 × 0.6 × 0.85 mm). The area corresponding to the stenotic lesion showed hyperintensity on noncontrast T1WI (Figure 3-B). On the next day, the patient underwent coronary angiography that showed 75% stenosis in the mid LAD (Figure 3-C) in the area corresponding to the HIP identified by T1WI. First, preinterventional OCT (ImageWire; LightLab Imaging, Inc, Westford, Massachusetts) imaging was performed on the culprit lesion in the LAD. The OCT images revealed an intracoronary thrombus, macrophages, and TCFA in the culprit lesion (Figure 3-D). Therefore, a filter-based distal protection device (Filtrap, Nipro, Japan) was deployed distal to the LAD lesion to reduce the risk of distal embolization. After stent implantation, ST-segment elevation persisted, and antegrade flow markedly diminished (Thrombolysis in Myocardial Infarction [TIMI] grade 1) (Figure 3-E). Removal of the distal protection device resulted in immediate normalization of flow with resolution of the ST-segment elevation. On inspection, the filter device contained a small amount of debris (Figure 4-A), which contained thrombus (Figure 4-B, C) and macrophages (Figure 4-D). The patient was safely discharged a few days later without any symptoms or abnormal findings on electrocardiography, echocardiography, and cardiac enzyme testing.

Figure 1
figure 1

MSCT coronary angiography at the first examination (A and B) and one year later (C and D). A, At the first examination, MSCT coronary angiography showed moderate stenosis (indicated by arrow) in the mid LAD (partial-width maximum intensity projection). The area of coronary stenosis is shown in higher magnification in panel B (maximum intensity projection). C and D, One year later, follow-up MSCT coronary angiography showed a slight progression of coronary stenosis.

Figure 2
figure 2

The exercise stress thallium-201 single-photon emission computed tomography. The exercise stress images (A-C) showed moderate defect in apico-anterior wall. The images at rest (D-F) showed redistribution in the same area. They revealed apico-anterior myocardial ischemia.

Figure 3
figure 3

The culprit lesion in the mid LAD. A, Whole-heart coronary MR angiographic image showed moderate coronary stenosis (indicated by arrowhead) in the mid LAD. B, Coronary T1WI image showed HIP (indicated by arrowhead) in the area corresponding to the moderate stenotic lesion. C, Coronary angiographic image showed moderate coronary stenosis in the mid LAD. D, OCT images showed intracoronary thrombus (1), macrophages (2), and thin-cap fibroatheroma (3) in the culprit lesion. E, Coronary angiographic image showed the filter no-reflow phenomenon after stent implantation.

Figure 4
figure 4

Photograph of the filter device and Micrographs of captured debris after the procedure. A, The filter device contained a small amount of debris. B, Immunostaining for platelets with anti-CD61 antibody. The specimen, stained withanti-CD61 antibody, was positive. C, An adjacent specimen, stained with anti-fibrinogen antibody, showed positivity for fibrinogen (indicated by arrows) to surround platelets. D, Immunostaining for macrophages with anti-CD68 antibody. The specimen contained CD68-positive macrophages.

Conclusions

It is unclear what caused the HIPs of the coronary artery on T1WI. There is a possibility that HIP formation detected on T1WI results from methemoglobin production, such as during intracoronary thrombus formation, intraplaque hemorrhage, or blood stasis. However, there are few reports of a lesion containing an intracoronary thrombus, detected as HIP on T1WI associated with the filter no-reflow phenomenon in a patient with silent myocardial ischemia. The present case shows that coronary HIPs on T1WI may help noninvasive identification of vulnerable plaques within the coronary arteries of the heart, regardless of the presence or absence of angina symptoms.

Consent

Written informed consent was obtained from the patient for the publication of this case report and accompanying images. A copy of the written consent is available for review by the Editor-in-Chief of this journal.

Abbreviations

HIP:

Hyperintense plaque

T1WI:

T1-weighted imaging

CMR:

Cardiovascular magnetic resonance

AMI:

Acute myocardial infarction

OCT:

Optical coherence tomography

TCFA:

Thin-cap fibroatheroma

SAP:

Stable angina pectoris

MSCT:

Multislice computed tomography

LAD:

Left anterior descending artery.

References

  1. Moody AR, Murphy RE, Morgan PS, Martel AL, Delay GS, Allder S, MacSweeney ST, Tennant WG, Gladman J, Lowe J, Hunt BJ: Characterization of complicated carotid plaque with magnetic resonance direct thrombus imaging in patients with cerebral ischemia. Circulation. 2003, 107: 3047-52. 10.1161/01.CIR.0000074222.61572.44.

    Article  PubMed  Google Scholar 

  2. Murphy RE, Moody AR, Morgan PS, Martel AL, Delay GS, Allder S, MacSweeney ST, Tennant WG, Gladman J, Lowe J, Hunt BJ: Prevalence of complicated carotid atheroma as detected by magnetic resonance direct thrombus imaging in patients with suspected carotid artery stenosis and previous acute cerebral ischemia. Circulation. 2003, 107: 3053-8. 10.1161/01.CIR.0000074204.92443.37.

    Article  PubMed  Google Scholar 

  3. Jansen CH, Perera D, Makowski MR, Wiethoff AJ, Phinikaridou A, Razavi RM, Marber MS, Greil GF, Nagel E, Maintz D, Redwood S, Botnar RM: Detection of intracoronary thrombus by magnetic resonance imaging in patients with acute myocardial infarction. Circulation. 2011, 124: 416-24. 10.1161/CIRCULATIONAHA.110.965442.

    Article  CAS  PubMed  Google Scholar 

  4. Ehara S, Hasegawa T, Nakata S, Matsumoto K, Nishimura S, Iguchi T, Kataoka T, Yoshikawa J, Yoshiyama M: Hyperintense plaque identified by magnetic resonance imaging relates to intracoronary thrombus as detected by optical coherence tomography in patients with angina pectoris. Eur Heart J Cardiovasc Imaging. 2012, 13: 394-9. 10.1093/ehjci/jer305.

    Article  PubMed Central  PubMed  Google Scholar 

  5. Hong MK, Mintz GS, Lee CW, Kim YH, Lee SW, Song JM, Han KH, Kang DH, Song JK, Kim JJ, Park SW, Park SJ: Comparison of coronary plaque rupture between stable angina and acute myocardial infarction: a three-vessel intravascular ultrasound study in 235 patients. Circulation. 2004, 110: 928-33. 10.1161/01.CIR.0000139858.69915.2E.

    Article  PubMed  Google Scholar 

  6. Kubo T, Imanishi T, Kashiwagi M, Ikejima H, Tsujioka H, Kuroi A, Ishibashi K, Komukai K, Tanimoto T, Ino Y, Kitabata H, Takarada S, Tanaka A, Mizukoshi M, Akasaka T: Multiple coronary lesion instability in patients with acute myocardial infarction as determined by optical coherence tomography. Am J Cardiol. 2010, 105: 318-22. 10.1016/j.amjcard.2009.09.032.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Shoichi Ehara.

Additional information

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

KM was the primary author of the text. SE conceived the report, acted as the chief editor, and provided the images. TY was the primary physician during the patient’s inpatient stay. TH, KO, TI, KS, and MY were involved in the patient’s care as well as editing and overseeing of the text. All authors have read and approved the final manuscript.

Authors’ original submitted files for images

Rights and permissions

Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution License ( https://creativecommons.org/licenses/by/2.0 ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Matsumoto, K., Ehara, S., Hasegawa, T. et al. A case of a lesion containing an intracoronary thrombus detected as hyperintense plaque on T1-weighted cardiovascular magnetic resonance in a patient with silent myocardial ischemia. J Cardiovasc Magn Reson 15, 50 (2013). https://doi.org/10.1186/1532-429X-15-50

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/1532-429X-15-50

Keywords