Skip to main content

Feasibility of high-resolution quantitative perfusion analysis in patients with heart failure

Abstract

Background

Cardiac magnetic resonance (CMR) is playing an expanding role in the assessment of patients with heart failure (HF). The assessment of myocardial perfusion status in HF can be challenging due to left ventricular (LV) remodelling and wall thinning, coexistent scar and respiratory artefacts. The aim of this study was to assess the feasibility of quantitative CMR myocardial perfusion analysis in patients with HF.

Methods

A group of 58 patients with heart failure (HF; left ventricular ejection fraction, LVEF ≤ 50%) and 33 patients with normal LVEF (LVEF >50%), referred for suspected coronary artery disease, were studied. All subjects underwent quantitative first-pass stress perfusion imaging using adenosine according to standard acquisition protocols. The feasibility of quantitative perfusion analysis was then assessed using high-resolution, 3 T kt perfusion and voxel-wise Fermi deconvolution.

Results

30/58 (52%) subjects in the HF group had underlying ischaemic aetiology. Perfusion abnormalities were seen amongst patients with ischaemic HF and patients with normal LV function. No regional perfusion defect was observed in the non-ischaemic HF group. Good agreement was found between visual and quantitative analysis across all groups. Absolute stress perfusion rate, myocardial perfusion reserve (MPR) and endocardial-epicardial MPR ratio identified areas with abnormal perfusion in the ischaemic HF group (p = 0.02; p = 0.04; p = 0.02, respectively). In the Normal LV group, MPR and endocardial-epicardial MPR ratio were able to distinguish between normal and abnormal segments (p = 0.04; p = 0.02 respectively). No significant differences of absolute stress perfusion rate or MPR were observed comparing visually normal segments amongst groups.

Conclusions

Our results demonstrate the feasibility of high-resolution voxel-wise perfusion assessment in patients with HF.

Background

Despite recent advances in diagnosis and management, heart failure (HF) remains a common cause of death and morbidity [1-3]. Myocardial ischemia is known to be one of the proposed pathophysiological mechanisms of HF and it is increasingly evident that the management of ischemia represents a potential therapeutic target for some of these patients [4-6].

In recent years, cardiovascular magnetic resonance (CMR) has established itself as an important component to the assessment and management of patients with coronary artery disease (CAD) and HF [7,8]. CMR is considered the reference method for the assessment of global and regional ventricular function and left ventricular wall mass [9]. CMR has become a robust and widely-available tool for assessment of ischaemic scar burden and myocardial perfusion imaging in patients with CAD [10-12] and can be used to help elucidate aetiology of HF [13]. However, there are no data currently available on the feasibility of perfusion CMR in patients with HF. The evaluation of myocardial perfusion status in patients with HF can be challenging due to LV remodelling and wall thinning, the presence of scar, and respiratory artefacts. 3 Tesla (3 T) kt CMR perfusion enables high spatial resolution perfusion assessment and provides data suitable for voxel-wise quantitative analysis [14,15]. The availability of combined methods for high-resolution imaging and voxel-wise quantitative assessment may enable the use of perfusion CMR to assess myocardial perfusion status also in patients with dilated and remodelled ventricles, although the evidence for this is lacking. Therefore, the aim of this study was to test the feasibility of 3 T kt high-resolution and voxel-wise quantitative perfusion CMR in this subgroup of patients.

Methods

We identified patients referred for perfusion CMR to assess HF aetiology. Patients were then retrospectively classified on the basis of the aetiology of HF as ischaemic (LVEF < 50% with scar arising from the subendocardium or transmural in a location corresponding to a coronary territory) or non-ischaemic (LVEF < 50%, either no scar or mid-myocardial or epicardial scar with invasive coronary angiogram confirming unobstructed epicardial coronary arteries) [13]. A group of patients with normal LV function (LVEF >50%) referred for suspected coronary artery disease were studied as control subjects.

All patients studied provided written consent (09/H0802/78) and the study was conducted in accordance with the Declaration of Helsinki.

Images were acquired on a Philips Achieva 3 T (TX) system, equipped with a 32-channel cardiac phased array receiver coil (Philips, Best, the Netherlands). First pass perfusion imaging consisted of a high-resolution kt turbo-gradient echo sequence (imaging parameters: shortest echo time (range 1.35 to 1.54 ms), shortest repetition time (range 2.64 to 3.12 ms), 18° flip angle, 90° saturation prepulse, 120 ms prepulse delay, typical TR 2.6 ms, typical TE 0.9 ms, typical spatial resolution 1.2×1.2×10mm. Three short-axis slices (basal, mid and apical) were acquired over every heartbeat covering 16 of the standard myocardial segments (segment 17 was excluded). Stress imaging preceded rest imaging by 14 ± 2 min (range 10 to 19 min). For stress imaging, 140 μg/kg/min of adenosine was administered intravenously for 4 min. Imaging commenced 3 min into the infusion and continued for 1 min during the acquisition of the images. All subjects were asked to abstain from caffeine and caffeine-containing food and drink for at least 24 hours before the scan, according to institutional practice.

Perfusion data were acquired during first pass injection of 0.075 mmol/kg Gadobutrol (Gadovist, Schering, Germany) at 4 ml/minute followed by a 20 ml saline flush. A dual bolus contrast agent scheme was used to correct for signal saturation of the arterial input function as previously described [16,17]. A correction map was created from a proton density-based image based on the same projections as the perfusion scans for correction of spatial inhomogeneities due to surface coils [18]. The CMR scan protocol included late gadolinium enhancement imaging for all subjects after a top up dose of contrast agent to a total dose of 0.2 mmol of gadolinium/kg of body weight.

Visual analysis

The studies were analyzed visually by two independent experts blinded to all other data. CMR scans were classified visually positive for ischemia in the presence of a perfusion defect (>60 degrees in either the basal or mid-ventricular slices, or >90 degrees in the apical slice) which was transmural, or involving ≥2 adjacent myocardial segments according to the criteria by Hussain et al. [16]. In the case of disagreement between observers, the images were reviewed together, and a consensus was reached. Late gadolinium enhancement and rest perfusion scans were then used to differentiate between stress-induced perfusion abnormalities and scar-related perfusion defects.

Quantitative analysis

An experienced operator, blinded to visual assessment and other clinical data, performed quantitative analysis using software and methods developed and previously validated against phantom and PET data [19,20]. The implementation of high-resolution signal intensity (SI) analysis required accurate respiratory motion correction and myocardial contour delineation. Respiratory motion was corrected using affine image registration by maximization of the joint correlation between consecutive dynamics within an automatically determined region of interest. A temporal maximum intensity projection was calculated to serve as a feature image for an automatic contour delineation method. The operator then manually optimized the automatically generated contours to avoid partial volume effects at the endocardial and epicardial border as previously described [21]. Areas of subendocardial dark-rim artefact occurring at the arrival of the main bolus of contrast agent in the LV were carefully excluded from the segmentation.

Quantitative perfusion analysis was performed by Fermi deconvolution according to the methods described by Wilke et al. [22] and Jerosch-Herold et al. [23] where time curves for the tissue impulse response function, h(t), were fitted to the Fermi function with the following analytical expression:

$$ h(t)=R\left[\frac{1}{{}_e\left(t-{\tau}_0-{\tau}_d\right){k}_{+1}}\right]u\left(t-{\tau}_d\right) $$

using a Marquardt-Levenberg nonlinear least square algorithm by letting k, R and τ 0 vary and keeping τ d fixed. In the above equation, u(t–τ d ) is the unit step function. The τ d accounts for the delay time between the appearance of the signal in the LV blood pool and myocardial region of interest (ROI) [24]. τ 0 characterizes the width of the shoulder of the Fermi function during which little or no contrast agent had left the ROI. R is the index of contrast agent influx parameter and k represents the decay rate of h(t) due to contrast agent washout. Using the above equation, myocardial blood flow (MBF) estimates are calculated as h(t) at t=0 [25]. Myocardial perfusion reserve (MPR) was calculated from division of stress perfusion rate by rest perfusion rate.

In addition, voxel-wise MPR results from the epicardial half (outer 50% transmural thickness) and from the endocardial half of each segment (inner 50% transmural thickness) were averaged and the endocardial to epicardial MPR ratio (endocardial MPR/epicardial MPR) was calculated.

Coronary angiography

Invasive coronary angiogram was performed on all patients with ischaemic cardiomyopathy or normal LV function within 6 months of the CMR scan.

Image quality

A visual score was given for image quality of each dataset using a four-point scale: 1—poor, 2—fair, 3—good, and 4— excellent. The severity of respiratory artefacts and dark rim artefacts were also scored on a four-point and three-point scale respectively. For respiratory artefacts: 1 – non-diagnostic; 2 – severe artefacts but diagnostic; 3 – mild artefacts; 4 – no artefacts. For dark rim artefacts: 1- circumferential; 2- segmental; 3- absent.

Statistical analysis

Data are presented as mean and standard deviation. Group means were compared using paired and unpaired Student t test and 1-way ANOVA as appropriate. The statistical analyses were performed using PASW software for Macintosh (IBM, Chicago, Illinois, version 21). Agreement between perfusion CMR and coronary angiography for the diagnosis of CAD was evaluated using a Kappa agreement test. Mann-Whitney and Chi-squared tests were used to test the qualitative measurements for statistical significance, with a p value threshold of 0.05.

Results

A total of 91 subjects were studied. This included 58 patients with HF (LVEF 39 ± 10%) and 33 patients with normal LV function (Normal LV group) (LVEF 64 ± 5%). In the HF group, 30 patients (51.7%) had a final diagnosis of ischaemic cardiomyopathy (ICM) and the remaining 28 subjects had a final diagnosis of non-ischaemic cardiomyopathy (NICM). Demographics, CMR structural findings and haemodynamic parameters are given in Table 1.

Table 1 Table showing demographic data and structural CMR findings for subjects studied

Visual analysis

In the ICM group, 25/30 (83%) patients showed evidence of a perfusion abnormality. Of these 19/25 (76%) patients showed stress-induced perfusion abnormalities, either extending beyond an area of scar or in an area served by a separate coronary territory. On segmental analysis, there were 73 segments showing stress-induced perfusion abnormalities (4.06 ± 2.05/patient). 90 segments showed scar-related perfusion abnormalities (4.29 ± 2.13/patient).

In the NICM group, no visual perfusion abnormalities were reported and 7/28 patients (for a total of 25 segments) showed late enhancement with a non-ischaemic-pattern [13].

15/33 (46%) patients in the Normal LV group showed stress-induced perfusion abnormalities, with a total number of 105 positive segments (6.4 ± 4.5/patient). No patients from the Normal LV group showed scar on late gadolinium enhancement images.

Quantitative analysis

Stress and rest perfusion estimates

Detailed results of stress and rest quantitative analysis are reported in Table 2.

Table 2 Table showing rest, stress and MPR perfusion values for groups studied

No significant difference in visually normal segments was observed between groups, with an average stress perfusion rate of 2.2 ± 1.0 ml/g/min in the ICM group, 1.9 ± 0.8 ml/g/min in the NICM group and 2.3 ± 1.3 ml/g/min in the Normal LV group (p = 0.18).

In the ICM group, there was a significant difference in stress perfusion rate between visually normal and abnormal segments (2.2 ± 1.0 ml/g/min vs 1.8 ± 0.9 ml/g/min, p = 0.02). The presence of ischaemic scar was associated with significantly reduced perfusion rate compared to visually normal segments (1.5 ± 0.8 ml/min vs 2.2 ± 1.0 ml/g/min; p = 0.005).

Within the Normal LV group, the difference in stress perfusion rate between visually normal and abnormal segments was less pronounced and not statistically significant (2.3 ± 1.3 ml/g/min vs 1.6 ± 0.8 ml/g/min, p = 0.08).

There was no significance difference in stress perfusion values between the ICM and Normal LV groups in visually abnormal segments (p = 0.47).

Examples of high-resolution, voxel-wise perfusion maps are given in Figures 1 and 2.

Figure 1
figure 1

Perfusion images from a HF patient with a circumflex coronary artery lesion causing a perfusion abnormality extending from base (A) to mid (B) to apical (C) level. Images seen vertically on the right show the perfusion maps corresponding to the ventricular level, the central column shows superimposed images. Note that there is mild respiratory artifact (white arrows) and that dark rim artifact seen in the apical inferoseptal wall (orange arrow).

Figure 2
figure 2

Perfusion images from three different HF patients with image on the left, perfusion map on the right and superimposed images in the centre. Row A shows thinning of the mid inferior wall with peri-infarct ischemia in the territory of the RCA. Row B shows ischemia in the territory of the LAD. Row C shows homogenous perfusion in a patient with thinned and dilated ventricle.

MPR

Detailed results of MPR analysis are also reported in Table 2.

No significant difference in visually normal segments was observed between groups, with an average MPR of 2.3 ± 0.8 in the ICM group, 2.2 ± 0.9 in the NICM group and 2.6 ± 1.1 in the Normal LV group (p = 0.19).

In the ICM group, there was a significant difference in MPR between visually normal and abnormal segments (2.3 ± 0.8 vs 1.8 ± 0.9, p = 0.04). The presence of ischaemic scar was associated with significantly reduced perfusion rate compared to visually normal segments (1.68 ± 0.08 vs 2.3 ± 0.8, p = 0.004).

Similarly, within the Normal LV group, the difference in MPR between visually normal and abnormal segments was statistically significant (2.6 ± 1.1 vs1.7 ± 0.8, p = 0.04).

There was no significance difference in MPR values between the ICM and Normal LV groups in visually abnormal segments (p = 0.62).

Endocardial-epicardial MPR ratio

There was no significant difference in the endo-epi MPR ratio in visually normal segments across groups with an endo-epi MPR ratio of 1.05 ± 0.16 in ICM patients, 1.02 ± 0.04 in NICM patients and 1.00 ± 0.06 in Normal LV patients (p = 0.57).

There was a significant difference in endo-epi MPR ratio between visually normal and visually abnormal non-scarred segments in both the ICM and Normal LV groups (ICM group: 1.04 ± 0.09 versus 0.96 ± 0.12 respectively, p = 0.02; Normal LV group: 1.00 ± 0.05 versus 0.93 ± 0.06 respectively, p = 0.02).

Coronary angiography

The results of invasive coronary angiography and perfusion CMR in relation to coronary artery territories, including Kappa results are detailed in Table 3.

Table 3 Table showing results of coronary angiography versus perfusion CMR results for patients in ICM and Normal LV groups

Image quality

Detailed results of overall image qualitative assessment, respiratory artefacts and dark rim artefacts are presented in Table 4 and Figure 3, with no significant differences observed between groups. The average angular extent of dark rim artefact was 27° (range 9-41°).

Table 4 Table showing results of the Chi-squared tests for qualitative assessment of image quality showing no significant differences between groups
Figure 3
figure 3

Figure showing the relative scores for image quality, respiratory artefacts and dark rim artefacts according to group.

Discussion

This study has several novel findings. Most importantly, it demonstrates the feasibility of quantitative first-pass perfusion analysis in patients with heart failure using a combination of high-resolution kt 3 T acquisition methods and high-resolution voxel-wise quantification. There were significant differences of MPR between visually normal and abnormal segments in both ICM and Normal LV groups. In the ICM group stress perfusion values were also statistically significant between visually normal and abnormal segments. However, this was not the case in the Normal LV group. This could be explained by the relatively low number of subjects positive for ischemia included in the study and is in keeping with previous validation studies that compared CMR perfusion and PET, showing good correlation for MPR values and weaker correlation for absolute stress perfusion values. This may relate to differences in the methods used for quantification such as the tracer properties, model assumptions, fitting methods and parameter constraints. MPR cancels out a degree of variability and this may help explain our results [26].

CMR is now well established for the evaluation of patients with coronary disease and heart failure. Perfusion CMR is increasingly used to determine aetiology of heart failure and to plan patient management. At the same time, CMR is now well established for the evaluation of patients with CAD and ischemia detection is rapidly becoming one of the main indications for CMR examination [27]. Studies have also shown that even in non-ischaemic cardiomyopathy the presence of ischemia has implications for the occurrence of adverse events [5,6,28].

Perfusion CMR has been previously shown to be at least as accurate as nuclear perfusion imaging in patients with angina [12,29,30] and quantitative perfusion CMR has been validated against FFR [31,32], microspheres [22,33], Single Photon Emission Computed Tomography (SPECT) [34] and Positron Emission Tomography (PET) [20].

Within the field of perfusion CMR, several technical developments have refined the sequences. The use of an advanced sequence such as kt sensitivity encoding allows considerable improvement in spatial resolution with improved image quality, signal-to-noise, contrast-to-noise and reduction in the transmural extent of dark-rim artefacts, particularly at 3 T [15]. The advantages of the kt sequence in comparison with standard perfusion CMR sequences when using visual assessment has been demonstrated in patients with normal LV function [14,35].

To our knowledge, there are no previous studies focusing on perfusion in patients with heart failure using CMR. Only a few studies, using PET, have been performed specifically exploring perfusion abnormalities in patients with HF and have produced conflicting results [36-38]. Van Den Heuvel et al. studied a group of NICM patients using PET and showed a similar perfusion rate at rest but reduced global myocardial perfusion reserve (MPR) versus a group of healthy controls [36]. In contrast, Neglia et al. showed a reduced MPR at rest as well as during pacing and pharmacological stress in patients with NICM [38]. The concept that even in NICM, the presence of silent ischemia may contribute to progressive impairment of LV function was supported by findings by a study by Tio et al. patients with NICM were assessed with PET and dobutamine stress [39]. They found that MPR was significantly higher in segments with higher contractile reserve and lower in the segments which did not change or deteriorated with stress.

Non-invasive assessment of myocardial perfusion in patients with HF can be challenging for a number of reasons. Foremost, in cases of advanced HF the LV wall is often thinner and remodeled, requiring higher spatial resolution to reliably identify subendocardial areas of stress-induced ischemia or areas of peri-infarct ischemia. PET is considered the reference standard for in-vivo quantitative perfusion assessment. However, it is limited by the intrinsically lower spatial resolution and this might become an important limiting factor for the assessment of dilated and remodelled ventricles.

Perfusion CMR, and in particular 3 T kt, offers higher spatial resolution and arguably is best placed to identify areas of ischemia in these patients. In addition, the advantage of CMR over other techniques to directly visualise scar enables more precise assessment of peri-infarct ischemia. This reduces the risk of including scarred areas in segmental averages of perfusion. Perfusion rate in areas of scar was found to be reduced which, if included in the analysis, could result in false positive ischemia results.

We observed a non-significant trend towards lower perfusion rates in visually normal segments of patients with NICM, which would be in keeping with the results previously obtained by PET. However, this comparison is beyond the scope of the study and would need to be addressed in future work.

Importantly, our results demonstrate a significant endocardial-epicardial MPR ratio in ischaemic segments, even in patients with HF who have thinned and remodelled ventricles. This is in keeping with findings of a study by Parodi et al. where microspheres were injected into hearts of patients at time of transplantation, demonstrating the presence of a perfusion gradient in the presence of extensive LV remodelling [40]. To our knowledge, our data are the first to show that non-invasive quantification of myocardial perfusion in multiple independent layers of myocardium is feasible also in this group of patients.

Perfusion assessment in patients with HF can be further complicated by a well-recognised irregularity in respiratory motion and reduced tolerance to breath-holding which can result in a reduction in image quality [41-43]. These respiratory artefacts are likely to affect kt sequences, used in this study, more significantly than other perfusion sequences. We did not observe this effect in our study, which may be a reflection of good patient coaching and careful selection of the time for the breath hold command.

Limitations of the study

  1. 1)

    This is a feasibility study. No reference standard except for visual assessment was used. However, visual assessment is considered the clinical diagnostic standard for perfusion CMR evaluation and extensive validation is available against Fractional Flow Reserve (FFR), invasive angiography, Single Positron Emission Computed Tomography (SPECT) and PET.

  2. 2)

    Though we were able to compare our findings with invasive coronary angiography, this serves as a limited reference method in the absence of invasive functional assessment of coronary flow reserve. Furthermore, the variability in coronary anatomy in terms of territory supplied, may underestimate the degree of correlation between the two techniques.

  3. 3)

    Results might not be easy to generalise to other CMR sequences and field-strengths, or to standard (segmental) quantitative analysis methods. The quantification process may need to be adjusted for other field strengths and perfusion sequences and this could form part of future work.

Conclusion

This study demonstrates that the combination of 3 T kt high-resolution perfusion CMR with high-resolution voxel-wise quantitative analysis appears feasible in this group of heart failure patients. This approach allows additional information gained from improved spatial resolution to be preserved, a feature that is of crucial importance in thinned and remodeled ventricles.

References

  1. Shaw LJ, Berman DS, Maron DJ, Mancini GBJ, Hayes SW, Hartigan PM, et al. Optimal medical therapy with or without percutaneous coronary intervention to reduce ischemic burden: results from the clinical outcomes utilizing revascularization and aggressive drug evaluation (COURAGE) trial nuclear substudy. Circulation. 2008;117:1283–91.

    Article  PubMed  Google Scholar 

  2. Cowie MR, Wood DA, Coats AJ, Thompson SG, Suresh V, Poole-Wilson PA, et al. Survival of patients with a new diagnosis of heart failure: a population based study. Heart. 2000;83(5):505-10.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  3. Hobbs FDR, Roalfe AK, Davis RC, Davies MK, Hare R, and the Midlands Research Practices Consortium (MidReC). Prognosis of all-cause heart failure and borderline left ventricular systolic dysfunction: 5 year mortality follow-up of the Echocardiographic Heart of England Screening Study (ECHOES). Eur Heart J. 2007;28:1128–34.

    Article  PubMed  Google Scholar 

  4. Neglia D, Michalassi C, Trivieri MG, Sambuceti G, Giorgetti A, Pratali L et al. Prognostic role of myocardial blood flow impairment in idiopathic left ventricular dysfunction. Circulation. 2002;105(2):186-93.

    Article  PubMed  Google Scholar 

  5. Fang W, Zhang J, He Z-X. Myocardial ischemia in patients with dilated cardiomyopathy. Nucl Med Commun. 2010;31:981–4.

    Article  PubMed  Google Scholar 

  6. Sobajima M, Nozawa T, Suzuki T, Ohori T, Shida T, Matsuki A, et al. Impact of myocardial perfusion abnormality on prognosis in patients with non-ischemic dilated cardiomyopathy. J Cardiol. 2010;56:280–6.

    Article  PubMed  Google Scholar 

  7. Abbasi SA, Ertel A, Shah RV, Dandekar V, Chung J, Bhat G, et al. Impact of cardiovascular magnetic resonance on management and clinical decision-making in heart failure patients. J Cardiovasc Magn Reson. 2013;15:1.

    Article  Google Scholar 

  8. Karamitsos TD, Francis JM, Myerson S, Selvanayagam JB, Neubauer S. The role of cardiovascular magnetic resonance imaging in heart failure. J Am Coll Cardiol. 2009;54:1407–24.

    Article  PubMed  Google Scholar 

  9. Myerson SG, Bellenger NG, Pennell DJ. Assessment of left ventricular mass by cardiovascular magnetic resonance. Hypertension. 2002;39:750–5.

    Article  CAS  PubMed  Google Scholar 

  10. Klein C. Assessment of myocardial viability with contrast-enhanced magnetic resonance imaging: comparison with positron emission tomography. Circulation. 2002;105:162–7.

    Article  PubMed  Google Scholar 

  11. Schwitter J, Nanz D, Kneifel S, Bertschinger K, Buchi M, Knusel PR, et al. Assessment of myocardial perfusion in coronary artery disease by magnetic resonance : a comparison with positron emission tomography and coronary angiography. Circulation. 2001;103:2230–5.

    Article  CAS  PubMed  Google Scholar 

  12. Schwitter J, Wacker CM, van Rossum AC, Lombardi M, Al-Saadi N, Ahlstrom H, et al. MR-IMPACT: comparison of perfusion-cardiac magnetic resonance with single-photon emission computed tomography for the detection of coronary artery disease in a multicentre, multivendor, randomized trial. Eur Heart J. 2008;29:480–9.

    Article  PubMed  Google Scholar 

  13. McCrohon JA. Differentiation of heart failure related to dilated cardiomyopathy and coronary artery disease using gadolinium-enhanced cardiovascular magnetic resonance. Circulation. 2003;108:54–9.

    Article  CAS  PubMed  Google Scholar 

  14. Morton G, Ishida M, Schuster A, Hussain S, Schaeffter T, Chiribiri A, et al. Perfusion cardiovascular magnetic resonance: comparison of an advanced, high-resolution and a standard sequence. J Cardiovasc Magn Reson. 2012;14:1.

    Article  Google Scholar 

  15. Plein S, Ryf S, Schwitter J, Radjenovic A, Boesiger P, Kozerke S. Dynamic contrast-enhanced myocardial perfusion MRI accelerated with k-t sense. Magn Reson Med. 2007;58:777–85.

    Article  PubMed  Google Scholar 

  16. Hussain ST, Paul M, Plein S, McCann GP, Shah AM, Marber MS, et al. Design and rationale of the MR-INFORM study: stress perfusion cardiovascular magnetic resonance imaging to guide the management of patients with stable coronary artery disease. J Cardiovasc Magn Reson. 2012;14:1.

    Article  Google Scholar 

  17. Ishida M, Schuster A, Morton G, Chiribiri A, Hussain S, Paul M, et al. Development of a universal dual-bolus injection scheme for the quantitative assessment of myocardial perfusion cardiovascular magnetic resonance. J Cardiovasc Magn Reson. 2011;13:28.

    Article  PubMed Central  PubMed  Google Scholar 

  18. Kremers FPPJ, Hofman MBM, Groothuis JGJ, Jerosch-Herold M, Beek AM, Zuehlsdorff S, et al. Improved correction of spatial inhomogeneities of surface coils in quantitative analysis of first-pass myocardial perfusion imaging. J Magn Reson Imaging. 2009;31:227–33.

    Article  Google Scholar 

  19. Zarinabad N, Chiribiri A, Hautvast GLTF, Ishida M, Schuster A, Cvetkovic Z, et al. Voxel-wise quantification of myocardial perfusion by cardiac magnetic resonance. Feasibility and methods comparison. Magn Reson Med. 2012;68:1994–2004.

    Article  PubMed  Google Scholar 

  20. Morton G, Chiribiri A, Ishida M, Hussain ST, Schuster A, Indermuehle A, et al. Quantification of absolute myocardial perfusion in patients with coronary artery disease. J Am Coll Cardiol. 2012;60:1546–55.

    Article  PubMed  Google Scholar 

  21. Hautvast G, Chiribiri A, Zarinabad N, Schuster A, Breeuwer M, Nagel E. Myocardial blood flow quantification from MRI by deconvolution using an exponential approximation basis. IEEE Trans Biomed Eng. 2012;59(7):2060–7.

  22. Wilke N, Jerosch-Herold M, Wang Y, Huang Y, Christensen BV, Stillman AE et al. Myocardial perfusion reserve: assessment with multisection, quantitative, first-pass MR imaging. Radiology. 1997;204(2):373-84

    Article  CAS  PubMed  Google Scholar 

  23. Jerosch-Herold M, Wilke N, Stillman AE, Wilson RF.Magnetic resonance quantification of the myocardial perfusion reserve with a Fermi function model for constrained deconvolution. Med Phys. 1998;25:73.

  24. Zarinabad N, Hautvast GL, Sammut E, Arujuna A, Breeuwer M, Nagel E, et al. Effects of tracer arrival time on the accuracy of high-resolution (voxel-wise) myocardial perfusion maps from contrast-enhanced first-pass perfusion magnetic resonance. IEEE Trans Biomed Eng. 2014;61(9):2499-506.

  25. Jerosch-Herold MM, Wilke NN, Stillman AEA. Magnetic resonance quantification of the myocardial perfusion reserve with a Fermi function model for constrained deconvolution. Med Phys. 1998;25:73–84.

    Article  CAS  PubMed  Google Scholar 

  26. Gerber BL. Quantification of myocardial perfusion and myocardial perfusion reserve by positron emission tomography and cardiovascular magnetic resonance imaging. J Am Coll Cardiol. 2012;60:1556–7.

    Article  PubMed  Google Scholar 

  27. Bruder O, Schneider S, Nothnagel D, Dill T, Hombach V, Schulz-Menger J, et al. EuroCMR (European Cardiovascular Magnetic Resonance) Registry. J Am Chem Soc. 2009;54:1457–66.

    Google Scholar 

  28. Neglia D. Prognostic role of myocardial blood flow impairment in idiopathic left ventricular dysfunction. Circulation. 2002;105:186–93.

    Article  PubMed  Google Scholar 

  29. Greenwood JP, Maredia N, Radjenovic A, Brown JM, Nixon J, Farrin AJ, et al. Clinical evaluation of magnetic resonance imaging in coronary heart disease: the CE-MARC study. Trials. 2009;10:62.

    Article  PubMed Central  PubMed  Google Scholar 

  30. Schwitter J, Arai AE. Assessment of cardiac ischaemia and viability: role of cardiovascular magnetic resonance. Eur Heart J. 2011;32:799–809.

    Article  PubMed Central  PubMed  Google Scholar 

  31. Lockie T, Ishida M, Perera D, Chiribiri A, De Silva K, Kozerke S, et al. High-resolution magnetic resonance myocardial perfusion imaging at 3.0-tesla to detect hemodynamically significant coronary stenoses as determined by fractional flow reserve. J Am Coll Cardiol. 2011;57:70–5.

    Article  PubMed  Google Scholar 

  32. Costa MA, Shoemaker S, Futamatsu H, Klassen C, Angiolillo DJ, Nguyen M, et al. Quantitative magnetic resonance perfusion imaging detects anatomic and physiologic coronary artery disease as measured by coronary angiography and fractional flow reserve. J Am Coll Cardiol. 2007;50:514–22.

    Article  PubMed  Google Scholar 

  33. Christian TF, Aletras AH, Arai AE. Estimation of absolute myocardial blood flow during first-pass MR perfusion imaging using a dual-bolus injection technique: comparison to single-bolus injection method. J Magn Reson Imaging. 2008;27:1271–7.

    Article  PubMed  Google Scholar 

  34. Lee DC. Magnetic resonance versus radionuclide pharmacological stress perfusion imaging for flow-limiting stenoses of varying severity. Circulation. 2004;110:58–65.

    Article  PubMed  Google Scholar 

  35. Motwani M, Maredia N, Fairbairn TA, Kozerke S, Radjenovic A, Greenwood JP, et al. High-resolution versus standard-resolution cardiovascular MR myocardial perfusion imaging for the detection of coronary artery disease. Circ Cardiovasc Imaging. 2012;5:306–13.

    Article  PubMed  Google Scholar 

  36. van den Heuvel AFM, van Veldhuisen DJ, van der Wall EE, Blanksma PK, Siebelink H-MJ, Vaalburg WM, et al. Regional myocardial blood flow reserve impairment and metabolic changes suggesting myocardial ischemia in patients with idiopathic dilated cardiomyopathy. J Am Coll Cardiol. 2000;35:19–28.

    Article  PubMed  Google Scholar 

  37. Masci PG, Marinelli M, Piacenti M, Lorenzoni V, Positano V, Lombardi M, et al. Myocardial structural, perfusion, and metabolic correlates of left bundle branch block mechanical derangement in patients with dilated cardiomyopathy: a tagged cardiac magnetic resonance and positron emission tomography study. Circ Cardiovasc Imaging. 2010;3:482–90.

    Article  PubMed  Google Scholar 

  38. Neglia D, Parodi O, Gallopin M, Sambuceti G, Giorgetti A, Pratali L, et al. Myocardial blood flow response to pacing tachycardia and to dipyridamole infusion in patients with dilated cardiomyopathy without overt heart failure: a quantitative assessment by positron emission tomography. Circulation. 1995;92:796–804.

    Article  CAS  PubMed  Google Scholar 

  39. Tio RA, Slart RHJA, de Boer RA, van der Vleuten PA, de Jong RM, van Wijk LM, et al. Reduced regional myocardial perfusion reserve is associated with impaired contractile performance in idiopathic dilated cardiomyopathy. Neth Heart J. 2009;17:470–4.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  40. Parodi O, De Maria R, Oltrona L, Testa R, Sambuceti G, Roghi A, et al. Myocardial blood flow distribution in patients with ischemic heart disease or dilated cardiomyopathy undergoing heart transplantation. Circulation. 1993;88:509–22.

    Article  CAS  PubMed  Google Scholar 

  41. Kremser CB, O’Toole MF, Leff AR. Oscillatory hyperventilation in severe congestive heart failure secondary to idiopathic dilated cardiomyopathy or to ischemic cardiomyopathy. Am J Cardiol. 1987;59:900–5.

    Article  CAS  PubMed  Google Scholar 

  42. Feld H, Priest S. A cyclic breathing pattern in patients with poor left ventricular function and compensated heart failure: A mild form of cheyne-stokes respiration. JACC. 1993;21(4):971-974

    Article  CAS  PubMed  Google Scholar 

  43. Yahima T, Koike A, Sugimoto K, Miyahara Y, Marumo F, Hiroe M. Mechanism of periodic breathing in patients with cardiovascular disease. Chest. 1994;106:142-146.

    Article  Google Scholar 

Download references

Acknowledgement

The acknowledgements are included in the Funding Sources section (NIHR and BRC) which can be separated from the grant details.

Funding sources

The Centre of Excellence in Medical Engineering funded by the Wellcome Trust and EPSRC under grant WT 088641/Z/09/Z. The authors acknowledge financial support from the Department of Health via the National Institute for Health Research (NIHR) comprehensive Biomedical Research Centre award to Guy’s and St Thomas’ NHS Foundation Trust in partnership with King’s College London.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Eva Sammut.

Additional information

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

ES and AC conceived and designed study. RR and GCW involved in design of the study. ES, MS and ZC responsible for data collection. ES wrote draft of manuscript. ES, NZ, RW and GM involved in analysis of results. All authors read and approved the final manuscript.

Rights and permissions

This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Sammut, E., Zarinabad, N., Wesolowski, R. et al. Feasibility of high-resolution quantitative perfusion analysis in patients with heart failure. J Cardiovasc Magn Reson 17, 13 (2015). https://doi.org/10.1186/s12968-015-0124-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12968-015-0124-2

Keywords