Free breathing contrast-enhanced time-resolved magnetic resonance angiography in pediatric and adult congenital heart disease

Abstract

Background

Contrast enhanced magnetic resonance angiography (MRA) is generally performed during a long breath-hold (BH), limiting its utility in infants and small children. This study proposes a free-breathing (FB) time resolved MRA (TRA) technique for use in pediatric and adult congenital heart disease (CHD).

Methods

A TRA sequence was developed by combining spiral trajectories with sensitivity encoding (SENSE, x4 kx-ky and x2 kz) and partial Fourier (75% in kz). As no temporal data sharing is used, an independent 3D data set was acquired every ~1.3s, with acceptable spatial resolution (~2.3x2.3x2.3mm). The technique was tested during FB over 50 consecutive volumes. Conventional BH-MRA and FB-TRA data was acquired in 45 adults and children with CHD. We calculated quantitative image quality for both sequences. Diagnostic accuracy was assessed in all patients from both sequences. Additionally, vessel measurements were made at the sinotubular junction (N = 43), proximal descending aorta (N = 43), descending aorta at the level of the diaphragm (N = 43), main pulmonary artery (N = 35), left pulmonary artery (N = 35) and the right pulmonary artery (N = 35). Intra and inter observer variability was assessed in a subset of 10 patients.

Results

BH-MRA had significantly higher homogeneity in non-contrast enhancing tissue (coefficient of variance, P <0.0001), signal-to-noise ratio (P <0.0001), contrast-to-noise ratio (P <0.0001) and relative contrast (P = 0.02) compared to the FB-TRA images. However, homogeneity in the vessels was similar in both techniques (P = 0.52) and edge sharpness was significantly (P <0.0001) higher in FB-TRA compared to BH-MRA. BH-MRA provided overall diagnostic accuracy of 82%, and FB-TRA of 87%, with no statistical difference between the two sequences (P = 0.77). Vessel diameter measurements showed excellent agreement between the two techniques (r = 0.98, P <0.05), with no bias (0.0mm, P = 0.71), and clinically acceptable limits of agreement (-2.7 to +2.8mm). Inter and intra observer reproducibility showed good agreement of vessel diameters (r>0.988, P<0.0001), with negligible biases (between -0.2 and +0.1mm) and small limits of agreement (between -2.4 and +2.5mm).

Conclusions

We have described a FB-TRA technique that is shown to enable accurate diagnosis and vessel measures compared to conventional BH-MRA. This simplifies the MRA technique and will enable angiography to be performed in children and adults whom find breath-holding difficult.

Background

Assessment of thoracic (or cardiac) anatomy is important in patients with congenital heart disease (CHD) and is one of the main indications for cardiovascular magnetic resonance (CMR) in this population [1]. Contrast enhanced MR angiography (CE-MRA) has a proven ability to detect vascular stenoses, dilation and other abnormalities [25] and is often used for this purpose. However, acquisition of high resolution, three-dimensional (3D) data is time consuming, normally taking between 10–25 s. Thus, to prevent image degradation as a result of respiratory motion, CE-MRA is generally performed during a breath-hold. Unfortunately, this limits the use of CE-MRA in small children (who are unable to comply with breath-hold instructions) and severely dyspnoeic adults. In these groups, a better approach might be to acquire each volume so quickly that respiratory motion has limited effect on image quality. This would enable CE-MRA to be performed during free-breathing and would open up this technique to a wider group of patients.

Such an approach has been partially realized by time resolved MR angiography (TRA), in which a series of volume angiograms are acquired in quick succession [7]. This technique is mainly used to provide information about perfusion kinetics [8,9], as well as to simplify scan timing in relation to the passage of the contrast bolus [10]. However, the majority of time-resolved MRA sequences use some form of data sharing across time (e.g. contrast-enhanced timing-robust angiography; CENTRA keyhole [11], sliding window [12], or time-resolved echo-shared angiographic technique; TREAT [13]), making them sensitive to respiratory motion artifacts. Thus, conventional TRA sequences are often performed during a breath-hold to ensure sufficient image quality.

In this study, we propose an alternative method of accelerating time resolved angiography; namely by combining time efficient spiral trajectories with sensitivity encoding (SENSE). The benefit of this approach is that there is no temporal data sharing. This may allow sufficient image quality to be achieved during free-breathing conditions. The specific aims of this study were; a) To demonstrate the feasibility of acquiring free-breathing time resolved MRA (FB-TRA) in pediatric and adult congenital heart disease, b) To quantitatively assess image quality of FB-TRA in comparison with a conventional breath-hold angiographic sequence (BH-MRA), c) To compare the diagnostic accuracy of FB-TRA to conventional BH-MRA, and d) To assess the accuracy and reproducibility of vessel measurements made from FB-TRA compared to BH-MRA.

Methods

Study population

Between June and July 2014, 45 consecutive children with heart disease (congenital and cardiomyopathy) and adults with congenital heart disease (32 male, 13 female) were enrolled into this study. Inclusion criteria were: a) Clinical referral for cardiac MR imaging and b) Clinically necessary CE-MRA. The exclusion criteria were general contraindications to MR, such as pregnancy or MR-incompatible implants. One further child was recruited in whom contrast administration was required for tissue characterization, but not CE-MRA. In this child it was possible to perform the conventional BH-MRA sequence during free breathing and compare with FB-TRA. The local research ethics committee approved the study and written consent was obtained from all subjects/guardians.

Imaging protocol

Imaging was performed on a 1.5 Tesla MR scanner (Avanto, Siemens Medical Solutions, Erlangen, Germany) using two spine coils and one body-matrix coil (giving a total of 12 coil elements). A 20–22 gauge plastic intravenous cannula was placed in the subject’s antecubital vein for administration of contrast agent. BH-MRA was performed as part of the clinical scan and FB-TRA was performed at the end of the clinical scan. The interval between the two scans was 29 ± 10 min (range: 10 to 48 min). The same contrast injection protocol was used for each scan; 0.2 mL/kg of Gadoteric acid (Dotarem, Guerbet, Roissy, France) up to a maximum of 10 mL, being injected at a rate of 2 mL/s. The specifics of the two MRA sequences are detailed below.

Breath-hold MRA sequence

BH-MRA was performed using a 3D Cartesian spoiled gradient echo (SPGR) sequence, acquired in the sagittal orientation. This sequence was accelerated with GRAPPA in the phase encode direction (full parameter details in Table 1). Optimal timing was ensured through the use of a 2D thick slab SPGR bolus tracking sequence. This sequence allowed visualization of contrast as it passed through the heart and great vessels, allowing the BH-MRA to be triggered when the contrast entered the relevant anatomy. In most patients, both left and right heart visualization was required and two angiograms (~13.5 s breath-hold each) were acquired after a single injection of contrast agent, with a 15 s pause between them. In a minority of patients who clinically required visualization of just one vascular bed, only pulmonary or aortic angiograms were acquired.

Table 1 Sequence parameters for the BH-MRA and FB-TRA sequences

Free-breathing TRA sequence

FB-TRA was performed using an in-house 3D stack-of-spirals SPGR sequence acquired in the transverse orientation. A uniform density spiral k-space filling strategy was used in kx-ky (readout duration ~5 ms), with 16 interleaves required to fill k-space at each of the 96 kz positions. In order to accelerate the acquisition, kx-ky data was undersampled by a factor of four and kz was undersampled by a factor of two. In addition, partial Fourier (75 %) was applied along kz. The sampling pattern in kx-ky was rotated by one position for each acquired kz position, in order to reduce artifacts [14]. This undersampled data was reconstructed online using an iterative non-Cartesian 3D SENSE algorithm [15], combined with a homodyne reconstruction [16]. In order to calculate the coil sensitivities from the data itself, the sampling pattern had to be rotated by one position in kx-ky for each volume and shifted by one position in kz every fourth volume. Combining eight consecutive volumes resulted in a fully sampled central 50 % of k-space, from which the coil sensitivities were calculated by dividing the corresponding image data by the sum of squares of all the coil data [17]. The necessary ‘reference data’ for the homodyne reconstruction was taken from the central kz positions of the acquired data [16]. The total acceleration factor achieved was 10.7x and enabled acquisition of an acceptable spatial resolution volume (~2.3×2.3×2.3 mm) every ~1.3 s. All sequence parameters can be seen in Table 1.

Image analysis

All image data was analyzed using the OsiriX open source DICOM viewing platform (Osirix 5.9, OsiriX foundation, Switzerland) [18]. The BH-MRA and FB-TRA data for each patient were separately anonymized using a random number identifier. All observers were blinded to the patient identity, the other MR data acquired as part of the clinical scan and the results of other diagnostic examinations. The specific image analysis procedures are described below.

Image quality

Quantitative image quality was assessed by measuring coefficient of variance (CoV), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), relative contrast (RC) and edge sharpness (by J.A.S, 7 years experience). The CoV and RC required measurement of the mean and standard deviation of signal intensities (SI, σ) in the blood pool and in a non-enhancing tissue. The blood pool measures were made using vessel regions-of-interest (ROI’s) placed at the sinotubular junction (Ao1) and main pulmonary artery (MPA) from the frame with the highest contrast. The spinal fluid (which is a non-contrast enhancing tissue) was used to make tissue measures. Vessel and tissue CoV and RC were then calculated as follows:

$$ \begin{array}{l}Co{v}_{vessel}=\frac{\sigma_{vessel}}{S{I}_{vessel}}\\ {}Co{v}_{tissue}=\frac{\sigma_{tissue}}{S{I}_{tissue}}\\ {}RC=\frac{\left(S{I}_{vessel}-S{I}_{tissue}\right)}{\left(S{I}_{vessel}+S{I}_{tissue}\right)}\end{array} $$

True quantification of SNR and CNR in images acquired using non-Cartesian parallel imaging is non-trivial, due to the uneven distribution of noise [19]. However, noise can be was estimated as σtissue allowing SNR and CNR to be calculated using the formula below [20,21];

$$ \begin{array}{l}SNR=\frac{S{I}_{vessel}}{\sigma_{tissue}}\\ {}CNR=\frac{\left(S{I}_{vessel}-S{I}_{tissue}\right)}{\sigma_{tissue}}\end{array} $$

Quantitative edge sharpness (ES) was calculated (from the frame with visually the highest contrast) by measuring the maximum gradient of the normalized pixel intensities across the border of the vessel of interest as previously described [22]. ES was calculated from multiplanar reformatted cross sectional images at six equidistant positions along the thoracic Aorta, and six positions along the pulmonary vasculature (four equidistant positions along the MPA and one in each of the branch PA’s).

Diagnostic accuracy

Assessment of the diagnostic accuracy of the two angiographic sequences was performed by two evaluators (V.M. with 12 years CMR experience, and B.P. with 4 years CMR experience) who were not involved in the clinical reporting of the CMR scans for the subjects in this study. Data from each angiographic sequence was separately consensus reviewed in a randomized order using multiplanar reformatting. It should be noted that all frames of the FB-TRA reformats were assessed. Six arterial segments (Aortic root (AoR), aortic arch (AoA), Descending aorta (DescAo), main pulmonary artery (MPA), right pulmonary artery (RPA) and left pulmonary artery (LPA)) were specifically assessed for the presence of stenosis and dilation. In addition, any other positive diagnoses were noted. The diagnosis from the angiographic data was compared to the diagnosis as stated in the clinical CMR report (as assessed from the whole CMR examination, including 3D whole heart imaging and selected cine, black blood and flow imaging).

Vessel measurements

One observer (V.M.) measured aortic and pulmonary artery diameters from multiplanar reformats, derived from the BH-MRA and FB-TRA. The FB-TRA multiplanar reformats had an additional temporal dimension and diameters were measured in the frame in which the vessel of interest had the greatest contrast and were displayed most sharply. Aortic diameter was assessed in three positions; the sinotubular junction (Ao1), the proximal descending aorta (Ao2) and descending aorta at the level of the diaphragm (Ao3). Pulmonary artery diameters were assessed in the MPA, the mid LPA and the mid RPA. Where a stenosis was present, the vessel diameter measurements were made at the position of the narrowing. Intraobserver variability (by V.M., > 7 days between measurements) of vessel diameter measurements from both sequences was assessed in a subset of 10 patients, who had both aortic and pulmonary BH-MRA. Additionally, interobserver variability of vessel diameter measurements was performed in these 10 patients (by V.M. and a second observer, B.P.).

Statistical analysis

All statistical analysis was performed using GraphPad Prism (GraphPad Software Inc., San Diego, CA). The results are expressed as the mean ± standard-deviation. Paired t-tests were used to compare BH-MRA and FB-TRA, in terms image quality and vessel diameter measurements. Additionally, correlation coefficients were calculated.

Diagnostic accuracy was assessed by calculation of the sensitivity and specificity of the BH-MRA and FB-TRA sequences, for the detection of stenosis and dilation. A Fisher’s exact test was used to assess if there were any significant differences in the diagnostic accuracy of the two techniques. The McNemar chi-squared statistical test was used to assess if there were any significance differences in the sensitivity or specificity of the two techniques.

Bland-Altman analysis was performed to give measures of agreement between the vessel diameter measurements from the two sequences, as well as inter and intra observer agreement [23]. One-way ANOVA tests were used to compare the difference in vessel diameter measurements from the two techniques, between all vessel segments. A P-value of less than .05 indicated a significant difference.

Results

The median age of the patients enrolled in the comparative arm of this study was 23.1 ± 15.7 years (range: 8 to 80 years, 13 of whom were less than 18 years old). The cardiovascular diagnoses in these patients were; repaired tetralogy of Fallot (n = 7); hypertrophic cardiomyopathy (n = 6); Marfan syndrome (n = 6); transposition of the great arteries, post arterial switch (n = 3), post atrial switch (n = 3); repaired coarctation of the aorta (n = 5); pulmonary stenosis (n = 3); repaired ventricular septal defect (n = 3); dilated aortic root (n = 2); repaired anomalous pulmonary venous drainage (n = 1); repaired atrial septal defect (n = 1); repaired truncus arteriosus (n = 1); cor triatriatum (n = 1); Ebstein’s anomaly (n = 1); subaortic stenosis (n = 1); and dilated right ventricle (n = 1).

FB-TRA data was successfully acquired in all 45 patients. In 33 patients both pulmonary and aortic BH-MRA’s were acquired, in 10 patients only an aortic BH-MRA was clinically indicated, and in the remaining two patients only a pulmonary BH-MRA was indicated. All subjects were able to follow breath-holding instructions.

The child in whom a free breathing BH-MRA (in both the pulmonary and aortic vasculature) was acquired was 10 years old and had a diagnosis of dilated cardiomyopathy.

Image quality

Figure 1 shows images acquired using the BH-MRA sequence but during free breathing. It should be noted that there is a loss of vessel edge sharpness and increased artifact due to respiratory motion. This is compared to the FB-TRA in the same patient, which has better edge definition and very little respiratory artifact (Fig. 1).

Fig. 1
figure 1

Example multiplanar reformatted image quality from BH-MRA acquired during free-breathing, and FB-MRA in a 10 year old patient with cardiomyopathy

In the comparative arm of the study, the image quality of both MRA sequences was good. The FB-TRA images contained some residual aliasing resulting from the high acceleration factor used, however these artifacts were mostly in the outer portions of the images. Figure 2 shows examples of the multiplanar reformatted image quality from the two sequences, in one 16 year old patient with an LPA stenosis. Figure 3 shows multiple frames from the FB-TRA sequence, compared to the BH-MRA sequence, in one 29 year old patient, who has an atrial switch – the full FB-TRA movie can be seen online in Additional file 1. Figure 4 shows multiple frames from a 3D reconstruction of the FB-TRA images, compared to the BH-MRA sequence, in one 41 year old patient showing kinking of the LPA – the full FB-TRA movie can be seen online in Additional file 2.

Fig. 2
figure 2

Example multiplanar reformatted image quality from one 16 year old patient with an LPA stenosis, from both BH-MRA and FB-TRA. * Ascending Aorta, § Left Pulmonary Artery, ^ Main Pulmonary Artery

Fig. 3
figure 3

Example image quality in multiple frames (denoted by the numbers in the table header) from the FB-TRA sequence compared to the BH-MRA sequence, in one 29 year old patient whom has undergone an atrial switch. The full movie can be seen online in Additional file 1. * Ascending Aorta, § Left Pulmonary Artery, ^ Main Pulmonary Artery

Fig. 4
figure 4

Multiple frames from a 3D reconstruction of the FB-TRA images (denoted by the numbers in the table header) compared to the BH-MRA sequence, in one patient showing kinking of the LPA. The full movie can be seen online in Additional file 2

Quantitative image quality results are shown in Table 2. Signal homogeneity (as measured using CoV) in the non-enhancing tissue was found to be significantly higher in the BH-MRA images compared to the FB-TRA images (P < 0.0001), however the vessels were found to have a similar homogeneity in both techniques (P = 0.52). The BH-MRA images had significantly higher SNR (P < 0.0001), CNR (P < 0.0001) and RC (P = 0.02) compared to the FB-TRA images. However, average edge sharpness was significantly (P < 0.0001) higher in the FB-TRA images compared to the BH-MRA images, although the standard deviation of ES was significantly higher in the FB-TRA images (P < 0.0001).

Table 2 Quantitative image quality results for the BH-MRA and FB-TRA sequences

Diagnostic accuracy

Anatomical lesions detected by assessment of the whole CMR as stated in the CMR report are listed in Table 3. The BH-MRA sequence provided the correct overall diagnosis in 37/45 patients (diagnostic accuracy = 82 %), and the FB-TRA sequence in 39/45 patients (diagnostic accuracy = 87 %), with no statistical difference between the two sequences (P = 0.77). The diagnostic failures are listed in Table 4. It should be noted that in four patients, both reviewers found the same, incorrect diagnosis in the BH-MRA and FB-TRA sequences. In two cases, dynamic kinking/obstruction were poorly appreciated on both ungated MRA sequences. In the third case, isolated valvar stenosis of a pulmonary homograft was not visible on either angiogram. In the remaining case a baffle leak post atrial switch was missed by the BH-MRA and FB-TRA sequences.

Table 3 Patient diagnosis
Table 4 Misdiagnosis

The specific ability of the two sequences to assess stenosis (N = 13) or dilation (N = 53) in the imaged vessel segments (N = 234) was also assessed. Overall, the BH-MRA sequence provided the correct diagnosis in 228/234 segments (diagnostic accuracy = 97 %) and the FB-TRA in 230/234 segments (diagnostic accuracy = 98 %), with no statistical difference between the groups (P = 0.75). The sensitivity of BH-MRA for specifically identifying stenosis was 62 % compared to 69 % for FB-TRA, with both having a specificity of 100 %. The sensitivity of BH-MRA for identifying dilation was 98 % and of FB-TRA was 100 %, with specificities of 100 % for both sequences. There were no statistical differences between the sequences in terms of sensitivity and specificity to stenosis (P = 0.56, P = 1.0 respectively) or dilation (P = 0.32, P = 1.0 respectively).

Vessel measurements

The vessel diameters were successfully measured in all 234 imaged vessel segments (Ao1, Ao2 and Ao3 in 43 patients, and MPA, RPA and LPA in 35 patients). Scatter and Bland Altman plots for all 234 segments are shown in Fig. 5 with excellent agreement (r = 0.98, P < 0.05), no bias (0.0 mm, P = 0.71), and clinically acceptable limits of agreement (−2.7 to +2.8 mm). There was similarly good agreement between BH-MRA and FB-TRA for each of the individual segments (see Table 5), with one-way ANOVA finding no statistical difference between segments (P = 0.1013).

Fig. 5
figure 5

Vessel diameters as measured in all 234 vessels from the BH-MRA and 637 FB-TRA sequences. a) Correlation, b) Bland-Altman Plot

Table 5 Vessel measurements

Inter and intra observer reproducibility showed good agreement of vessel diameters (r > 0.988, P < 0.0001), with negligible biases (between −0.2 and +0.1 mm) and small limits of agreement (between −2.4 and +2.5 mm). See Table 6 for results.

Table 6 Intra and inter observer variability

Discussion

We have shown that it is possible to perform free-breathing high spatio-temporal resolution time resolved angiography, in a population of 45 patients with paediatric and adult congenital heart disease. This was achieved through the use of a highly accelerated 3D stack of spirals acquisition with no data sharing between frames. The main findings were; i) FB-TRA was feasible in all patients, ii) FB-TRA had lower SNR, CNR and RC than BH-MRA, iii) FB-TRA had a similar diagnostic accuracy to BH-MRA, and iv) Vessel measurements made with the two sequences were comparable.

Time resolved angiography

The main aim of this study was to demonstrate that rapid acquisition allows angiographic data to be acquired during free-breathing. Rapid acquisition is the hallmark of time resolved angiography and we employed this approach in the current study. However, unlike the majority of TRA sequences, our implementation did not rely on data sharing techniques such as sliding window reconstruction [12], CENTRA keyhole [11] or TREAT [13]. Instead, we used a combination of efficient k-space filling with spiral trajectories, sensitivity encoding and partial Fourier to achieve rapid acquisition (~1.3 s/volume). The benefit of this approach is that data used for reconstruction of each volume only contains a limited amount of respiratory motion. We were able to show that this resulted in better image quality compared to conventional MR angiography performed during free breathing (duration ~13 s). Slightly unexpectedly, we also found that FB-TRA images had significantly higher average edge sharpness than BH-MRA images. This is probably due to BH-MRA including more cardiac motion (10–15 heart beats) than FB-TRA (1–2 heart beats) resulting in more edge blurring, despite the breath-hold.

Highly undersampled spiral imaging does have some disadvantages. The main drawback is increased signal inhomogeneity due to spiral off-resonance effects, trajectories errors and data undersampling [27]. In our study, FB-TRA images had significantly lower SNR, CNR and tissue signal homogeneity compared to BH-MRA images. However, vessel signal homogeneity was similar for both sequences. This was probably due to less variation in contrast concentration during the rapid FB-TRA acquisition (~1.3 s) compared to the longer BH-MRA acquisition (~13.5 s), which would compensate for the increased noise. In addition, RC was only marginally higher in BH-MRA, demonstrating that there are only small differences in the tissue contrast provided by these two sequences. As will be discussed later, the similarity of these metrics may explain the comparable diagnostic accuracy. Alternative reconstruction algorithms could also be investigated to improve the image quality of the FB-TRA sequence. The most promising is compressed sensing (CS), which is well suited to angiography due to the inherent sparseness of the data [24]. However, CS reconstructions are more computationally intensive than our proposed approach and could only be justified if they significantly improved image quality.

Another problem with spiral imaging relates to the orientation of the imaging slab. In Cartesian imaging, readout oversampling reduces artifact from signal outside the FOV in the frequency encode direction. This allows the BH-MRA to be acquired in the sagittal orientation for optimization of coverage, acquisition time and coil placement for parallel imaging. In spiral imaging there is no single ‘readout direction’, preventing oversampling being used to reduce artifact. Thus, FB-TRA data had to be acquired in the transverse orientation to reduce the amount of signal outside the FOV. Although this may not be the optimal orientation in terms of coverage, this limitation is offset by the greater efficiency and possible undersampling available with spiral imaging.

Diagnostic accuracy

The FB-TRA and BH-MRA were found to have statistically comparable overall diagnostic accuracy, as well as similar sensitivity and specificity for detection of stenosis and dilatation. This demonstrates that although SNR and CNR were lower in FB-TRA images, diagnostic accuracy was not significantly affected. However, it should be noted that both MRA sequences missed lesions in four out of 45 patients. In all these cases, MRA failed because the lesions were dynamic, membranous or intra-cardiac, situations where ungated imaging is known to struggle [25]. This justifies the use of multiple CMR sequences when attempting to make a comprehensive diagnosis in CHD.

In terms of vessel measurements, there was also excellent agreement between FB-TRA and BH-MRA, with no bias and clinically acceptable limits of agreement. Furthermore, there was no difference in intra and inter observer variability. This suggests that despite the reduction in image quality, FB-TRA allows accurate and reproducible quantitative and qualitative assessment of vascular structure. This may partly be related to the fact that RC and CoVvessel, which both specifically relate to vessel visualization, were similar in the FB-TRA and BH-MRA sequences. In addition, improved edge sharpness may compensate for any reduction in SNR and CNR.

Clinical utility

The main clinical advantage of our technique, is that it can be performed during free-breathing. This opens up the possibility of performing MRA in patients who are unable to breath hold. However, in this study we chose patients who were able to comply with breath-hold instructions for two reasons. Firstly, at our institution children who require vascular assessment, but cannot breath hold, undergo CMR under general anaesthetic. This makes it difficult to perform a comparative study of BH-MRA and FB-TRA in this population. Secondly, to demonstrate the comparable utility of FB-TRA, it was essential that the BH-MRA be performed in an optimal way (i.e. during a breath hold). Thus, further studies are required to investigate the utility of FB-TRA in small children (<8 years). In particular, the requirement for higher resolution imaging (with the commensurate loss of SNR and CNR) and problems with higher respiratory rates would have to be addressed.

A further benefit of time resolved MRA sequences, is that it is not necessary to calculate exact bolus timing [10]. This may significantly simplify workflow, helping to reduce overall scan times and increase throughput. Finally, time resolved MRA also allows assessment of perfusion kinetics [26], which although not specifically assessed in this study, may be beneficial in certain groups of patients.

Limitations

In this study, the BH-MRA sequence was always performed before FB-TRA sequence (~29 min between the two MRA scans). This was done to ensure that the clinically indicated BH-MRA was not affected by residual contrast (mean half-life of Dotarem is ~2.0/1.4 h in male/female subjects). However, this means that the FB-TRA may have been adversely affected by the contrast given for the BH-MRA. Thus, the results presented here give a conservative estimation of the FB-TRA technique in terms of image quality and diagnostic accuracy.

It was not possible to truly anonymize the BH-MRA data from the FB-TRA data, due to the temporal dimension of the TRA data. This meant that it was not possible to compare subjective image quality measures from the two sequences, as it is likely to be influenced by observer bias.

A final limitation of this technique is that the current online reconstruction is time consuming, taking approximately one hour for all 50 frames of FB-TRA data. However, the development of new highly parallel architectures, such as graphical processing units, should be able to significantly speed this up, as the pixel-wise calculations can be parallelized [28]. Alternatively, the reconstruction time could be reduced with the use of a bolus tracking sequence to visualize the contrast arriving in vasculature of interest, and trigger the start of the FB-TRA sequence, thereby reducing the amount of data acquired.

Conclusions

To conclude, we have described a free-breathing, time-resolved 3D spiral MRA technique that has been shown to enable accurate diagnosis and vessel measures compared to conventional breath-hold, Cartesian MRA. This technique simplifies the MRA technique and will enable angiography to be performed on children and adults in whom breath-holding is difficult.

Abbreviations

2D:

Two-dimensional

3D:

Three-dimensional

Ao1:

Sinotubular junction

Ao2:

Proximal descending aorta

Ao3:

Descending aorta at the level of the diaphragm

AoA:

Aortic arch

AoR:

Aortic root

BH-MRA:

Breath-hold magnetic resonance angiography

CE-MRA:

Contrast enhanced magnetic resonance angiography

CENTRA:

Contrast-enhanced timing-robust angiography

CHD:

Congenital heart disease

CMR:

Cardiovascular magnetic resonance

CNR:

Contrast-to-noise ratio

CS:

Compressed Sensing

DescAo:

Descending aorta

FB-TRA:

Free-breathing time resolved magnetic resonance angiography

FOV:

Field-of-view

LA:

Left atrium

LPA:

Left pulmonary artery

LSCA:

Left subclavian artery

MPA:

Main pulmonary artery

PDA:

Patent ductus arteriosus

RC:

Relative contrast

RCA:

Right coronary artery

ROI:

Region-of-interest

RPA:

Right pulmonary artery

SENSE:

Sensitivity encoding

SI:

Signal intensity

SNR:

Signal-to-noise ratio

SV:

Single ventricle

TRA:

Time resolved magnetic resonance angiography

TREAT:

Time-resolved echo-shared angiographic technique

VSD:

Ventricular septal defect

References

  1. Ntsinjana H, Hughes M, Taylor A. The role of cardiovascular magnetic resonance in pediatric congenital heart disease. J Cardiovasc Magn Reson. 2011;13:51.

    Article  PubMed Central  PubMed  Google Scholar 

  2. Greil GF, Powell AJ, Gildein HP, Geva T. Gadolinium-enhanced three-dimensional magnetic resonance angiography of pulmonary and systemic venous anomalies. J Am Coll Cardiol. 2002;39:335–41.

    Article  PubMed  Google Scholar 

  3. Prasad SK, Soukias N, Hornung T, Khan M, Pennell DJ, Gatzoulis MA, et al. Role of magnetic resonance angiography in the diagnosis of major aortopulmonary collateral arteries and partial anomalous pulmonary venous drainage. Circ. 2004;109:207–14.

    Article  Google Scholar 

  4. Ferrari VA, Scott CH, Holland GA, Axel L, St. John Sutton M. Ultrafast three-dimensional contrast-enhanced magnetic resonance angiography and imaging in the diagnosis of partial anomalous pulmonary venous drainage. J Am Coll Cardiol. 2001;37:1120–8.

    Article  CAS  PubMed  Google Scholar 

  5. Valsangiacomo E, Levasseur S, McCrindle B, MacDonald C, Smallhorn J, Yoo S-J. Contrast-enhanced MR angiography of pulmonary venous abnormalities in children. Ped Radiol. 2003;33:92–8.

    Article  Google Scholar 

  6. Geva T, Greil GF, Marshall AC, Landzberg M, Powell AJ. Gadolinium-enhanced 3-dimensional magnetic resonance angiography of pulmonary blood supply in patients with complex pulmonary stenosis or atresia: comparison with X-Ray angiography. Circ. 2002;106:473–8.

    Article  Google Scholar 

  7. Korosec FR, Frayne R, Grist TM, Mistretta CA. Time-resolved contrast-enhanced 3D MR angiography. MRM. 1996;36:345–51.

    Article  CAS  Google Scholar 

  8. Krishnam MS, Tomasian A, Lohan DG, Tran L, Finn JP, Ruehm SG. Low-dose, time-resolved, contrast-enhanced 3D MR angiography in cardiac and vascular diseases: correlation to high spatial resolution 3D contrast-enhanced MRA. Clinical Radiology. 2008;63:744–755.

  9. Fenchel M, Saleh R, Dinh H, Lee MH, Nael K, Krishnam M, et al. Juvenile and adult congenital heart disease: time-resolved 3D contrast-enhanced MR angiography. Radiology. 2007;244:399–410.

    Article  PubMed  Google Scholar 

  10. Wieben O, Grist TM, Hany TF, Thornton FJ, Glaser JK, Skuldt DH, et al. Time-resolved 3D MR angiography of the abdomen with a real-time system. MRM. 2004;52:921–6.

    Article  Google Scholar 

  11. Willinek WA, Gieseke J, Conrad R, Strunk H, Hoogeveen R, von Falkenhausen M, et al. Randomly segmented central k-space ordering in high-spatial-resolution contrast-enhanced MR angiography of the supraaortic arteries: initial experience. Radiology. 2002;225:583–8.

    Article  PubMed  Google Scholar 

  12. Zhu H, Buck DG, Zhang Z, Zhang H, Wang P, Stenger VA, et al. High temporal and spatial resolution 4D MRA using spiral data sampling and sliding window reconstruction. MRM. 2004;52:14–8.

    Article  Google Scholar 

  13. Fink C, Ley S, Kroeker R, Requardt M, Kauczor H-U, Bock M. Time-resolved contrast-enhanced three-dimensional magnetic resonance angiography of the chest: combination of parallel imaging with view sharing (TREAT). Investig Radiol. 2005;40:40–8.

    Google Scholar 

  14. Shin T, Nayak KS, Santos JM, Nishimura DG, Hu BS, McConnell MV. Three-dimensional first-pass myocardial perfusion MRI using a stack-of-spirals acquisition. MRM. 2013;69:839–44.

    Article  Google Scholar 

  15. Pruessmann KP, Weiger M, Bornert P, Boesiger P. Advances in sensitivity encoding with arbitrary k-space trajectories. MRM. 2001;46:638–51.

    Article  CAS  Google Scholar 

  16. Noll DC, Nishimura DG, Macovski A. Homodyne detection in magnetic resonance imaging. Med Imaging IEEE Trans. 1991;10:154–63.

    Article  CAS  Google Scholar 

  17. Nezafat R, Kellman P, Derbyshire JA, McVeigh ER. Real time high spatial-temporal resolution flow imaging with spiral MRI using auto-calibrated SENSE. IEEE Eng Med Biol Soc. 2004;1:1914–7.

    Google Scholar 

  18. Rosset A, Spadola L, Ratib O. OsiriX: an open-source software for navigating in multidimensional DICOM images. J Digit Imaging. 2004;17:205–16.

    Article  PubMed Central  PubMed  Google Scholar 

  19. Dietrich O, Raya JG, Reeder SB, Reiser MF, Schoenberg SO. Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters. JMRI. 2007;26:375–85.

    Article  PubMed  Google Scholar 

  20. Buerke B, Allkemper T, Kugel H, Bremer C, Evers S, Kooijman H, et al. Qualitative and quantitative analysis of routinely postprocessed (CLEAR) CE-MRA data sets: Are SNR and CNR calculations reliable? Acad Radiol. 2008;15:1111–7.

    Article  PubMed  Google Scholar 

  21. Dabir D, Naehle CP, Clauberg R, Gieseke J, Schild H, Thomas D. High-resolution motion compensated MRA in patients with congenital heart disease using extracellular contrast agent at 3 Tesla. J Cardiovasc Magn Reson. 2012;14:75.

    Article  PubMed Central  PubMed  Google Scholar 

  22. Steeden JA, Atkinson D, Hansen MS, Taylor AM, Muthurangu V. Rapid flow assessment of congenital heart disease with high-spatiotemporal-resolution gated spiral phase-contrast MR imaging. Radiology. 2011;260:79–87.

    Article  PubMed Central  PubMed  Google Scholar 

  23. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of cliical measurement. Lancet. 1986;i:307–10.

    Article  Google Scholar 

  24. Rapacchi S, Han F, Natsuaki Y, Kroeker R, Plotnik A, Lehrman E, et al. High spatial and temporal resolution dynamic contrast-enhanced magnetic resonance angiography using compressed sensing with magnitude image subtraction. MRM. 2014;71:1771–83.

    Article  Google Scholar 

  25. Naehle CP, Kaestner M, Müller A, Willinek WW, Gieseke J, Schild HH, et al. First-pass and steady-state MR angiography of thoracic vasculature in children and adolescents. J Am Coll Cardiol Img. 2010;3:504–13.

    Article  Google Scholar 

  26. Ingrisch M, Maxien D, Schwab F, Reiser MF, Nikolaou K, Dietrich O. Assessment of pulmonary perfusion with breath-hold and free-breathing dynamic contrast-enhanced magnetic resonance imaging: quantification and reproducibility. Investig Radiol. 2014;49:382–9. 310.1097/RLI.0000000000000020.

    Article  Google Scholar 

  27. Block KT, Frahm J. Spiral imaging: a critical appraisal. J Magn Reson Imaging. 2005;21:657–68.

    Article  PubMed  Google Scholar 

  28. Stone SS, Haldar JP, Tsao SC, Hwu WW, Sutton BP, Liang ZP. Accelerating advanced MRI reconstructions on GPUs. J Parallel Distrib Comput. 2008;68:1307–18.

    Article  PubMed Central  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jennifer A Steeden.

Additional information

Competing interests

The authors declare that they have no competing interests

Authors’ contributions

JAS: Design and programming of imaging sequence and reconstruction, acquisition of data, image quality processing, data interpretation, drafting of manuscript. BP: Vessel diameter measurements (observer 2), consensus reviewing for diagnosis. OT: Acquisition of data, preliminary data analysis/interpretation. VM: Study design, vessel diameter measurements (observer 1), consensus reviewing for diagnosis data interpretation, drafting of manuscript. All authors performed critical revision and approved the final manuscript.

Additional files

Additional file 1:

Movie showing FB-TRA sequence in one 29 year old patient whom has undergone an atrial switch. Left: Coronal, Middle: Sagittal, Right: Axial.

Additional file 2:

Movie showing 3D reconstruction of FB-TRA images, in one 41 year old patient, showing kinking of the LPA. Left: Front view, Right: Back view.

Rights and permissions

This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Steeden, J.A., Pandya, B., Tann, O. et al. Free breathing contrast-enhanced time-resolved magnetic resonance angiography in pediatric and adult congenital heart disease. J Cardiovasc Magn Reson 17, 38 (2015). https://doi.org/10.1186/s12968-015-0138-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12968-015-0138-9

Keywords