Incremental diagnostic utility of delayed enhancement CMR tissue characterization for detection of catheter associated right atrial thrombus

Background

Right atrial thrombus (RT) provides a rationale for anticoagulation and substrate for embolic events. CMR is well validated for thrombus detection, but has yet to be used to assess prevalence and predictors of RA thrombus among at risk cohorts.

Methods

The population comprised consecutive patients with central venous catheters undergoing CMR at Memorial Sloan Kettering Cancer Center (NY, NY). Delayed enhancement CMR (inversion recovery GRE) was used to identify RT; defined as a right atrial (RA) mass with avascular tissue characteristics (non-enhancing) on "long TI" (600msec) DE-CMR. Cine-CMR (SSFP) was used to quantify cardiac structure and function, including RA and RV function and chamber size. Clinical indices were categorized based on medical record review. Echo (if performed within 14 days of CMR) was retrieved from image archives and independently read for RT. Clinical records were queried for documented pulmonary embolus (PE) within 60 days of CMR.

Results

50 cancer patients (50±17yo, 64% female) with RA catheters were studied. CMR was performed for evaluation of a suspected RA mass (36%) or unrelated clinical indications (64%). RT was present in 22% (n=11); all had RT avascularity confirmed by dedicated "long TI" DE-CMR. Among affected patients, 63% had a solitary RT (36% multiple). Patients with RT had similar right-sided structure and function vs. those without RT based on RA end-diastolic area (10.2±3.5 vs. 10.2±2.1 cm2/m2, p= 0.94), RA end-systolic area (6.9±3.7 vs. 6.6±1.9 cm2/m2, p=0.76), RV end-diastolic volume (73±21 vs. 67±16 ml/m2, p= 0.27), and RVEF (57±8 vs. 59±9%, p= 0.40). Cancer diagnosis (73 vs. 85% solid tumor, p=0.39), catheter depth (2.3±2.2 vs. 2.1±1.8cm from RA/SVC junction, p=0.74), age and gender (both p=NS) were similar between groups. Transthoracic echo, attained 4.1±3.8 days from CMR in 50% of the population, demonstrated high sensitivity (89%) but moderate specificity (75%) in relation to DE-CMR. Cine-CMR yielded similar sensitivity (82%) but improved specificity (97%) vs. the reference standard of DE-CMR (Table). 27% of patients (3/11) with RT on DE-CMR had PE; all occurred prior to DE-CMR (average of 14 days before). Conversely, no PEs occurred among patients without RT. Clinical embolic events were independent of RT size (3.0±2.6cm2 vs. 2.6±1.3cm2, p=0.75).

Conclusions

Catheter associated RT occurs independently of right-sided structure or function, and is associated with clinical embolic events. Morphologic imaging by cine-CMR and echo provide limited diagnostic utility for RT as established by DE-CMR tissue characterization.

Funding

None.

Table 1 Diagnostic performance of anatomic imaging for right atrial thrombus by DE-CMR tissue characterization.

Author information

Authors and Affiliations

Authors

Rights and permissions

Open Access  This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made.

The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.

To view a copy of this licence, visit https://creativecommons.org/licenses/by/4.0/.

The Creative Commons Public Domain Dedication waiver (https://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Plodkowski, A., Kukar, N., Gupta, D. et al. Incremental diagnostic utility of delayed enhancement CMR tissue characterization for detection of catheter associated right atrial thrombus. J Cardiovasc Magn Reson 17 (Suppl 1), P327 (2015). https://doi.org/10.1186/1532-429X-17-S1-P327

Download citation

  • Published:

  • DOI: https://doi.org/10.1186/1532-429X-17-S1-P327

Keywords