Left and right ventricular kinetic energy using time-resolved versus time-average ventricular volumes
Journal of Cardiovascular Magnetic Resonance volume 17, Article number: P67 (2015)
Background
Four-dimensional flow-sensitive (4D flow) MRI opens the possibility for finding new, non-invasive measures of cardiac function, including KE. Studies using 4D flow MRI have reported correlations between disease states and altered KE profiles. However, the majority of these studies have relied on time-averaged (TA) segmentation rather than time-resolved (TR) segmentation largely because segmenting throughout the cardiac cycle (TR) is time-consuming and labor intensive. The purpose of this study was to determine if there are significant differences between KE profiles calculated using TR and TA segmentation of the right and left ventricles (RV, LV).
Methods
Time-resolved 4D flow MRI (PC VIPR, phase contrast with vastly undersampled isotropic projection reconstruction) data were acquired from 10 healthy volunteers on a 3T scanner (MR750, GE Healthcare, Waukesha, WI). RV and LV volumes were segmented from TR and TA images using Mimics (Materialise, Leuven, Belgium). Velocity profiles were obtained using Ensight (CEI, Apex, NC), and the total KE in each ventricle was calculated from both the TR and TA segmentations using MatLab (The Mathworks, Natick, MA). KE profiles were then compared using paired Student's t-tests.
Results
Small yet significant differences in calculated KE were observed between TR and TA segmentation. The peak systolic KE of the RV were 4.89±1.49 mJ using TR and 5.53±1.62 mJ using TA segmentation (P =0.016), while the peak systolic LV KE were 3.29±0.96 mJ and 4.16±1.26 mJ (P = 0.005). The peak diastolic RV KE were 3.33±0.90 mJ (TR) and 3.61±1.12 mJ (TA) (P = 0.082), while the peak diastolic LV KE were 4.90±1.49 mJ and 5.31±1.59 mJ (P = 0.044). The total integrated KE of the RV across the cardiac cycle were 1880±506 mJ (TR) and 2131±608 mJ (TA) (P = 0.004), while the integrated KE of the LV were 1775±510 mJ and 2080±658 mJ (P = 0.001).
Conclusions
KE profiles for both the right and left ventricles were determined using TR and TA segmentation. Although qualitatively the two methods resulted in comparable results, TA segmentation consistently over-estimated KE, with differences between the two methods being more pronounced during systole and particularly in the LV. Therefore, for a qualitative analysis, using TA images for segmentation is recommended, while a more accurate, quantitative analysis requires a full TR segmentation.
Funding
N/A.
Author information
Authors and Affiliations
Rights and permissions
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
About this article
Cite this article
Hussaini, S.F., Roldán-Alzate, A. & Francois, C.J. Left and right ventricular kinetic energy using time-resolved versus time-average ventricular volumes. J Cardiovasc Magn Reson 17 (Suppl 1), P67 (2015). https://doi.org/10.1186/1532-429X-17-S1-P67
Published:
DOI: https://doi.org/10.1186/1532-429X-17-S1-P67